Schlussbericht
(Englisch)
|
Within this project, small-size testing equipment of EPFL, dedicated to the measurement of thermal characteristics of soils as well of geothermal probes has been modified. Its caracteristics and performance have been improved with a decreased pressure head in the water circuit. The circulation pump, the flowmeter and the flow regulator valve have been replaced. The remote data transmission system has been changed completely to use a network primarily dedicated to data transmission. The fill circuit has also been modified. The increased possibilites with this optimised Mini-module enables carrying out thermal response tests in borehole heat exchangers of more fhan 300m depth.
Auftragnehmer/Contractant/Contraente/Contractor:
Autorschaft/Auteurs/Autori/Authors: Laloui,Dr. Lyesse Steinmann,Gilbert
Zugehörige Dokumente
|
Schlussbericht
(Französisch)
|
Dans le cadre de ce mandat, Le Mini-module de chauffage de l'EPFL destiné à la détermination des caractéristiques thermiques des sols et des sondes géothermiques a été modifié. Ses caractéristiques et performances ont été grandement améliorées par une diminution des pertes de charges dans le circuit d'eau. La pompe de circulation, le débit-mètre et la vanne de réglage du débit ont été remplacés. Le système de télétransmission a été complètement changé pour utiliser un réseau dédié prioritairement à la transmission de données. Le circuit de remplissage a également été modifié. L'éventail des possibilités d'utilisation de ce Mini-module optimisé permet actuellement d'effectuer des tests de réponse thermique des terrains avec des sondes de plus de 300 m de profondeur.
Auftragnehmer/Contractant/Contraente/Contractor:
Autorschaft/Auteurs/Autori/Authors: Laloui,Dr. Lyesse Steinmann,Gilbert
Zugehörige Dokumente
|