Research unit
SFOE
Project number
SI/500921
Project title
Market Study installed base and potential for energy efficiency on distribution Iransformers in Switzerland

Texts for this project

 GermanFrenchItalianEnglish
Key words
-
-
-
Anzeigen
Short description
Anzeigen
-
-
Anzeigen
Publications / Results
Anzeigen
Anzeigen
-
-
Final report
Anzeigen
Anzeigen
-
Anzeigen

Inserted texts


CategoryText
Key words
(English)
Market Study, Distribution Transformers, Energy Efficiency, Amorphous Transformers, Low Loss Transformers
Short description
(German)
Ziel der Studie ist eine Erfassung des aktuellen Bestandes an Verteiltransformatoren in den Netzebenen 5-7 in der Schweiz sowie die Erarbeitung und Abschätzung von Verbesserungs- und Einsparpotentialen sowie resultierenden Kosten und Payback durch den teilweisen oder vollständigen Ersatz der bestehenden Basis mittels hocheffizienter neuer Verteiltransformatoren.

ln der Studie werden die aktuellen Leerlauf- und Betriebsverluste der installierten Basis mit dem Stand der Technik verglichen und Schwerpunktszenarien sowie Handlungsalternativen für die Entscheidungsträger erarbeitet (z.B. Labelling).

Die Studie zeigt potentielle Hemmnisse und mögliche Aktionen zu deren Beseitigung auf.
Short description
(English)
The study targets to assess the installed base of distribution Iransformers in Switzerland (MV/LV, grid Ieveis 5-7). lt works out improvement potentials with respect to energy efficiency and describes related costs and payback for the partial or full replacement of the installed base using highly efficient distribution transformers.

The study compares operational Iosses of the installed base with state-of-the-art technology and works out seenarios for decision making (e.g. labeling).

The study elaborates potential obstacles and points out possible actions to eliminate.
Publications / Results
(German)
Related documents
Publications / Results
(French)
Related documents
Final report
(German)
Verteiltransformatoren der Mittelspannungs‐/Niederspannungsebene kommen in grosser Stückzahl zu Einsatz und haben eine lange Lebensdauer. Mithilfe von modernen Transformatoren mit amorphem Eisenkernmaterial können Leerlauf‐ und Lastverluste reduziert werden. Basierend auf Marktdaten wurde der Bestand, Altersstruktur, Leerlauf‐ und Lastverluste sowie das Einsparpotential durch den Ersatz der installierten Basis ermittelt. Es kann von einer Gesamtzahl von 70‘000 – 80‘000 installierten Verteilnetztransformatoren in der Schweiz auf der Netzebene NE5 ausgegangen werden. Im arithmetischen Mittel weisen die Transformatoren ein Alter von 23 Jahren auf. Knapp 50% aller installierten Transformatoren sind vor 1990 installiert worden. In den nächsten 10 Jahren werden 60% der Transformatoren 40 Jahre und älter sein. Die Verluste die zum jetzigen Zeitpunkt installierten Verteiltransformatoren im Schweizer Gesamtnetz belaufen sich auf rund 406GWh pro Jahr. Würden die effizientesten amorphen Transformatoren eingesetzt, ergäben sich Stromeinsparungen in Höhe von 204GWh pro Jahr. Im Mittel können in den gebräuchlichsten drei Leistungsklassen 2,9MWh (400kVA), 3,6MWh (630kVA) resp. 2,8MWh (1000kVA) pro Trafo pro Jahr eingespart werden.

Auftragnehmer/Contractant/Contraente/Contractor:
ABB Schweiz AG, Country Service Organisation

Autorschaft/Auteurs/Autori/Authors:
Dreyer,Karin
Streicher-Porte,Martin
Related documents
Final report
(English)
Distribution transformers in Switzerland are installed on several grid levels below sub‐transmission. This study focuses on the savings potential by replacing distribution transformers below 24 kV. It is deducted from several sources that a total amount of 70.000 to 80.000 units are installed in the Swiss grid, with an average age of 23 yrs. The overall losses of this installed base are around 406 GWh / yr. Distribution transformers are often operated at 25…40 % of their nominal load, where the iron‐ or no‐load losses are most stringent. By replacing the installed base with highly efficient transformers based on amorphous cores, these losses might be significantly reduced, the study deducts a savings potential of up to 204 GWh or roughly 50% of the current losses. Focused on the three mostly commonly installed transformer type classes, the savings potential per unit is on average estimated as following: 2,9MWh (400kVA), 3,6MWh (630kVA) and 2,8MWh (1000kVA). These 3 classes might be focused on in a first step as the total savings potential estimated here are 132 GWh (52.4 GWh, 64.6 GWh and 15.4 GWh).

Auftragnehmer/Contractant/Contraente/Contractor:
ABB Schweiz AG, Country Service Organisation

Autorschaft/Auteurs/Autori/Authors:
Dreyer,Karin
Streicher-Porte,Martin
Final report
(French)
En Suisse, les transformateurs de distribution des niveaux moyenne/basse tensions sont utilisés en grand nombre et ils ont une longue durée de vie. Grâce aux transformateurs modernes équipé d’un noyau en matériau ferreux amorphe, il est possible de réduire les pertes à vide et sous charge. Sur la base des données du marché les points suivant ont pu être investigué : le nombre d’unité, la distribution de l’âge des installions, les pertes à vide et sous‐charge, ainsi que le potentiel d’économie au travers du remplacement des unités installée. On peut partir du principe qu’il entre 70'000 et 80'000 transformateur de distribution installé en Suisse au niveau de tension NE5. La moyenne arithmétique de l’âge de transformateur indique un âge moyen de 23 ans. Prés de 50% de tous les transformateurs installés ont été installé avant 1990. Dans les prochains dix ans 60% des transformateurs auront 40 ans et plus. Les pertes de tous les transformateurs de distribution installés jusqu’à maintenant sur tout le réseau Suisse se monte à 406 GWh par an. En installant les transformateurs les efficients avec un noyau ferreux amorphe, alors l'économie d’électricité pourrait se monter jusqu’à hauteur de 204 GWh par an. En se concentrant sur les trois classes de puissance, les plus communément installées, soit 400 kVA, 630 kVA et 1'000 kVA, alors le potentiel d’économie annuel moyen par transformateur a été estimé respectivement à 2.9 MWh, 3.6 MWh et 2.8 MWh.

Auftragnehmer/Contractant/Contraente/Contractor:
ABB Schweiz AG, Country Service Organisation

Autorschaft/Auteurs/Autori/Authors:
Dreyer,Karin
Streicher-Porte,Martin