En-tête de navigationNavigation principaleSuiviFiche


Unité de recherche
PCRD EU
Numéro de projet
96.0263
Titre du projet
Network: Perfect crystal neutron optics
Titre du projet anglais
Network: Perfect crystal neutron optics

Textes relatifs à ce projet

 AllemandFrançaisItalienAnglais
Mots-clé
-
-
-
Anzeigen
Autre Numéro de projet
-
-
-
Anzeigen
Programme de recherche
-
-
-
Anzeigen
Description succincte
-
-
-
Anzeigen
Autres indications
-
-
-
Anzeigen
Partenaires et organisations internationales
-
-
-
Anzeigen
Résumé des résultats (Abstract)
-
-
-
Anzeigen
Références bases de données
-
-
-
Anzeigen

Textes saisis


CatégorieTexte
Mots-clé
(Anglais)
Neutron physics; neutron optics; perfect crystals; ultra small angle neutron scattering (USANS)
Autre Numéro de projet
(Anglais)
EU project number: FMRXCT960057
Programme de recherche
(Anglais)
EU-programme: 4. Frame Research Programme - 10.1 Stimulation of training and mobility
Description succincte
(Anglais)
See abstract
Autres indications
(Anglais)
Full name of research-institution/enterprise:
Paul Scherrer Institut PSI / ETH Zürich
Labor für Neutronenstreuung
Partenaires et organisations internationales
(Anglais)
Atominstitut der österreichischen Universitäten, Wien, ISIS Spallation Neutron Source, Didcot (UK)
Résumé des résultats (Abstract)
(Anglais)
The main work in 2001 was the experimental comparison of the new crystal design set up with other concepts. The new crystal design is based on channel cut Si (111) crystals for 3 reflections each, where the backside of the individual crystals is not plane parallel to the reflecting surface. By successively changing from single reflection, plane parallel crystals to the mentioned new design and by introducing Cd in the beam path at several positions, the theoretical explanation for the origin of the worse resolution of the old crystal design could be confirmed.
For these measurements the background on the TOPSI beamline at the spallation neutron source SINQ at PSI was reduced by new shielding. In this way the signal to background ratio could be improved by more than one order of magnitude compared to former measurements. It was shown that a mechanical coupling and a vibration reduction by an optical bench is not necessary. The much simpler set up with the monochromator crystal on the second axis of TOPSI and the analyzer crystal on the detector arm gave the same resolution.
Ultra small angle neutron scattering (USANS) will be a permanent option on TOPSI. For this purpose a series of constructive modifications are being performed. A repetition of the mentioned measurements on the reflectometer ADAM at the Institute Laue-Langevin (ILL) at Grenoble showed that background is still the limiting factor on TOPSI, so the main effort has to be put on new detector shielding.

Publication: M. Villa: 'Optimiertes Kristalldesign für ein Doppelkristall-Diffraktometer''
(PhD Thesis, TU Vienna, 2002).
Références bases de données
(Anglais)
Swiss Database: Euro-DB of the
State Secretariat for Education and Research
Hallwylstrasse 4
CH-3003 Berne, Switzerland
Tel. +41 31 322 74 82
Swiss Project-Number: 96.0263