ServicenavigationHauptnavigationTrailKarteikarten


Research unit
COST
Project number
C16.0034
Project title
Large-scale particle timing detector using plastic-scintillator and silicon-photomultiplier technologies

Texts for this project

 GermanFrenchItalianEnglish
Key words
-
-
-
Anzeigen
Research programs
-
-
-
Anzeigen
Short description
-
-
-
Anzeigen
Further information
-
-
-
Anzeigen
Partners and International Organizations
-
-
-
Anzeigen
Abstract
-
-
-
Anzeigen
References in databases
-
-
-
Anzeigen

Inserted texts


CategoryText
Key words
(English)
plastic scintillator; silicon photomultiplier; waveform digitiser; time resolution; SHiP experiment
Research programs
(English)
COST-Action TD1401 - Fast advanced Scintillator Timing
Short description
(English)
The aim of this project is to develop and test plastic scintillator bars coupled to large-area silicon photomultipliers (SiPMs) for a large detector with high timing precision. Such a detector is motivated by the SHiP experiment at the CERN SPS, proposed to search for hidden particles with masses below 2 GeV. In particular, SHiP can probe right-handed neutrinos with couplings that would explain the puzzles of neutrino masses, dark matter, and matter-antimatter asymmetry. The timing detector plays an essential role for background rejection in SHiP. The 6x12 m2 array placed in a magnetic field needs to separate out-of-time signals with a precision of 100 ps or better. The specific challenge of this project is therefore to design a cheap scintillator array with very good timing over a large surface. A 2 m long bar read out by PMTs on both ends is known to provide a time resolution around 100 ps. A novel design, made affordable by recent developments in SiPM technologies, is proposed here: the direct application of largearea SiPMs to the bar surface. This can potentially result in a better timing performance while also allowing the use of shorter bars. This concept, which can have many applications in the broader community, will be demonstrated in this project through a comprehensive set of measurements. In 2018, the optimised design and performance of the timing detector will be summarised in the SHiP technical design report requested by the CERN SPSC committee.
Further information
(English)
Full name of research-institution/enterprise: University of Geneva Département de physique nucléaire et corpusculaire Section de Physique - DPNC
Partners and International Organizations
(English)
AT; BE; BA; BG; HR; CZ; DK; EE; FI; FR; MK; DE; EL; HU; IS; IE; IL; IT; LV; LT; MT; MNE; NL; NO; PL; PT; RO; RS; SI; ES; SE;TR; UK; AL; CA
Abstract
(English)
See short description
References in databases
(English)
Swiss Database: COST-DB of the State Secretariat for Education and Research Hallwylstrasse 4 CH-3003 Berne, Switzerland Tel. +41 31 322 74 82 Swiss Project-Number: C16.0034