En-tête de navigationNavigation principaleSuiviFiche


Unité de recherche
COST
Numéro de projet
C16.0032
Titre du projet
Solar Energy Balanced Facade - SEBF
Titre du projet anglais
Solar Energy Balanced Facade - SEBF

Textes relatifs à ce projet

 AllemandFrançaisItalienAnglais
Mots-clé
-
-
-
Anzeigen
Programme de recherche
-
-
-
Anzeigen
Description succincte
-
-
-
Anzeigen
Autres indications
-
-
-
Anzeigen
Partenaires et organisations internationales
-
-
-
Anzeigen
Résumé des résultats (Abstract)
-
-
-
Anzeigen
Références bases de données
-
-
-
Anzeigen

Textes saisis


CatégorieTexte
Mots-clé
(Anglais)
Building envelope; adaptive facade; solar facade; advanced facade; adaptive thermal insulation; energy balance;thermal storage; curtain wall
Programme de recherche
(Anglais)
COST-Action TU1403 - Adaptive Facades Network
Description succincte
(Anglais)
Reducing the building energy consumption and carbon dioxide emissions are two of the most important challenges facing the building industry.The energy consumption of a building is directly related to its façade. Multi-functional and adaptive building envelopes can provide step-change improvements in the energy efficiency of new and refurbished buildings while improving the wellbeing of building occupants. The review of existing façade systems and ongoing research show that transparent and opaque façades are generally considered separately. This is why a new hybrid façade system, a transparent–opaque solar façade which incorporates seasonal adaptive daily solar-gain management to achieve an improved energy balance – is proposed: the solar-energy balanced façade (SEBF) system. The idea is to improve the thermal performance of the transparent part by utilizing the opaque thermal mass with a minimum amount of technical installation. While the basic structure of the facade meets the current static requirements, the additional adaptive features provide a much better adaptive energy performance. The SEBF supports HVAC systems rather than hindering or restricting their function, which satisfies the basic requirement of system separation.
Autres indications
(Anglais)
Full name of research-institution/enterprise: Hochschule Luzern Technik & Architektur Kompetenzzentrum Fassaden- und Metallbau
Partenaires et organisations internationales
(Anglais)
AT; BE; HR; CZ; DK; FR; MK; DE; EL; HU; IE; IL; IT; LV; LT; NL; NO; PL; PT; RS; SK; SI; ES; SE; UK; BG; CN;LIE ; AU
Résumé des résultats (Abstract)
(Anglais)
See short description
Références bases de données
(Anglais)
Swiss Database: COST-DB of the State Secretariat for Education and Research Hallwylstrasse 4 CH-3003 Berne, Switzerland Tel. +41 31 322 74 82 Swiss Project-Number: C16.0032