En-tête de navigationNavigation principaleSuiviFiche


Unité de recherche
INNOSUISSE
Numéro de projet
13757.1;5 PFFLE-LS
Titre du projet
Multimodal catheter for cardiovascular diagnosis
Titre du projet anglais
Multimodal catheter for cardiovascular diagnosis

Textes relatifs à ce projet

 AllemandFrançaisItalienAnglais
Description succincte
Anzeigen
-
-
Anzeigen
Résumé des résultats (Abstract)
Anzeigen
-
-
Anzeigen

Textes saisis


CatégorieTexte
Description succincte
(Allemand)
Multimodal catheter for cardiovascular diagnosis
Description succincte
(Anglais)
Multimodal catheter for cardiovascular diagnosis
Résumé des résultats (Abstract)
(Allemand)
Vulnerable plaque and stenosis reduce the cross-section of blood vessels and is one of the main origins of cardio-vascular diseases such as myocardial infarction, stroke and cardiac death. Diagnosis using stress tests or coronary angiography allow large-scale screening and identify patients at risk. However, direct and fast characterization of the clinical relevance of the coronary lesion is still an unsolved issue in many patients. This project aims mounting hot filament anemometry devices onto an existing commercial guide wire allowing real-time monitoring of the local speed of the flowing blood in the vessel. According to Bernoulli the local speed of a liquid is directly linked to cross-section reduction of a vessel. Marking the position of this throat allows subsequent clinical decision making for treatment. In a second step, the deposition of thin-film ultrasound pulse-echo devices onto the guide wire is projected to complete global clinical diagnosis.
Résumé des résultats (Abstract)
(Anglais)
Vulnerable plaque and stenosis reduce the cross-section of blood vessels and is one of the main origins of cardio-vascular diseases such as myocardial infarction, stroke and cardiac death. Diagnosis using stress tests or coronary angiography allow large-scale screening and identify patients at risk. However, direct and fast characterization of the clinical relevance of the coronary lesion is still an unsolved issue in many patients. This project aims mounting hot filament anemometry devices onto an existing commercial guide wire allowing real-time monitoring of the local speed of the flowing blood in the vessel. According to Bernoulli the local speed of a liquid is directly linked to cross-section reduction of a vessel. Marking the position of this throat allows subsequent clinical decision making for treatment. In a second step, the deposition of thin-film ultrasound pulse-echo devices onto the guide wire is projected to complete global clinical diagnosis.